APC Back-UPS CS Range
 |
 |
 |
| ~ 0:48 (Hours : Minutes) |
~ 0:52 (Hours : Minutes) |
~ 1:14 (Hours : Minutes) |
| Output |
| 210 Watts / 350 VA |
300 Watts / 500 VA |
400 Watts / 650 VA |
| 210 Watts / 350 VA |
300 Watts / 500 VA |
400 Watts / 650 VA |
| 230V |
230V |
230V |
(1.0) IEC 320 C13 (Surge Protection)
(3.0) IEC 320 C13 (Battery Backup) |
(1.0) IEC 320 C13 (Surge Protection)
(3.0) IEC 320 C13 (Battery Backup)
(2.0) IEC Jumpers (Surge Protection) |
(1) IEC 320 C13 (Surge Protection)
(3) IEC 320 C13 (Battery Backup) |
| Input |
| 230V |
230V |
230V |
| 50/60Hz+/-3Hz (autosensing) |
50/60Hz+/-3Hz (autosensing) |
50/60Hz+/-3Hz (autosensing) |
| IEC-320-C14inlet |
IEC-320-C14inlet |
IEC-320C14 |
| 1.83 meters |
1.83 meters |
1.83 meters |
| 196-280V |
196-280V |
196-280V |
| -- |
160-300V |
160-28 |
|
Batteries & Runtime
|
| Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
| 6 hour(s) |
6 hour(s) |
8 hour(s) |
| RBC2 |
RBC2 |
RBC17 |
| 1 |
1 |
1 |
|
Communications & Management
|
| DB-9 RS-232,USB |
DB-9 RS-232,USB |
USB |
| LED status display with On Line : On Battery : Replace Battery and Overload indicators |
| Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
|
Surge Protection and Filtering
|
| 300 Joules |
300 Joules |
320 Joules |
| Full time multi-pole noise filtering : 5% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
-- |
| RJ-45 Modem/Fax protection (two wire single line) |
Analog phone line for phone/fax/modem/DSL (RJ-45 connector) |
|
Physical
|
| 165.00 mm |
165.00 mm |
165.00 mm |
| 91.00 mm |
91.00 mm |
91.00 mm |
| 284.00 mm |
284.00 mm |
284.00 mm |
| 6.32 KG |
6.32 KG |
6.32 KG |
| 7.05 KG |
7.05 KG |
7.05 KG |
| 178 mm |
178 mm |
494.00 mm |
| 241.00 mm |
241.00 mm |
185.00 mm |
| 368.00 mm |
368.00 mm |
368.00 mm |
| Beige |
Beige |
Beige |
| 1073130401634 9 |
107 31304 01635 6 |
-- |
| 96 |
96 |
-- |
| -- |
-- |
1.00 |
| -- |
-- |
16.09 lbs. |
|
Environmental
|
| 0 - 40 °C |
0 - 40 °C |
0 - 40 °C |
| 0 - 95% |
0 - 95% |
5 - 95% |
| 0-3000 meters |
0-3000 meters |
0-3000 meters |
| -15 - 45 °C |
-15 - 45 °C |
-15 - 45 °C |
| 0 - 95% |
0 - 95% |
5 - 95% |
| 0-15000 meters |
0-15000 meters |
0-4500 meters |
| 40 dBA |
40 dBA |
45.00 dBA |
| 19 BTU/hr |
24 BTU/hr |
0.00 BTU/hr |
|
Conformance
|
| C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
A-tick,C-tick,CE,GOST,NEMKO |
| 2 years repair or replace |
| Lifetime : 100000 Euro,Lifetime : 50000 GBP |
| 1,3 |
1,3 |
3,6 |
|
|
|