APC Smart-UPS SC Range
Back-UPS ES
Click on the arrow to view more products
 |
 |
 |
| ~ 0:55 (Hours : Minutes) |
~ 1:40 (Hours : Minutes) |
~ 3:03 (Hours : Minutes) |
| Output |
| 260 Watts / 420 VA
|
390 Watts / 620 VA |
670 Watts / 1000 VA |
| 260 Watts / 420 VA
|
390 Watts / 620 VA |
670 Watts / 1000 VA |
| 230V |
| Less than 5% at full load |
| 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60
Hz nominal |
| up to 5 : 1 |
(1.0) IEC 320 C13
(3.0) IEC 320 C13
(2.0) IEC Jumpers |
(8) IEC 320 C13
(2) IEC Jumpers |
| -- |
Stepped approximation to a sinewave |
Sine wave |
| -- |
-- |
Configurable for 220 : 230 or 240 nominal output voltage |
| Input |
| 230V |
| 50/60 Hz +/- 3 Hz (auto sensing) |
| IEC-320 C14 |
IEC-320-C14 inlet |
IEC-320 C14 |
| 160 - 286V |
| 151 - 302V |
|
Batteries & Runtime
|
| Maintenance-free sealed Lead-Acid battery with
suspended electrolyte : leakproof |
| 3 hour(s) |
5.50 hour(s) |
3 hour(s) |
| RBC2 |
RBC4 |
RBC6 |
| 1 |
|
Communications & Management
|
| DB-9 RS-232 |
DB-9 RS-232,SmartSlot,USB |
| LED status display with On Line : On Battery :
Replace Battery and Overload indicators |
LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : and Overload Indicators |
| Alarm when on battery : distinctive low battery
alarm : overload continuous tone alarm |
Alarm when on battery : distinctive low battery alarm :
configurable delays |
| N/A |
Optional |
| -- |
1 |
|
Surge Protection and Filtering
|
| 320 Joules |
| Full time multi-pole noise filtering : 0.7%
IEEE surge let-through : zero clamping response time : meets UL 1449 |
| RJ-45 Modem/Fax/DSL/10-100 Base-T protection |
-- |
|
Physical
|
| 168.00 mm
|
216.00 mm |
| 119.00 mm
|
170.00 mm |
| 368.00 mm
|
375.00 mm |
439.00 mm |
| 9.09 KG
|
12.27 KG |
18.86 KG |
| 10.23 KG
|
13.18 KG |
20.91 KG |
| 318.00 mm
|
381.00 mm |
| 262.00 mm
|
330.00 mm |
| 508 mm
|
584.00 mm |
| Grey
|
Black |
| 40
|
24.00 |
|
Environmental
|
| 0 - 40 °C |
| 0 - 95% |
| 0-3000 meters |
| -15 - 45 °C |
| 0 - 95% |
| 0-15000 meters |
| 45 dBA |
45.00 dBA |
41.00 dBA |
| 50 BTU/hr |
70.00 BTU/hr |
100.00 BTU/hr |
|
Conformance
|
| CE,GOST,VCCI,VDE |
C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
| 2 years repair or replace |
| 2,3,11,12 |
2,3,11 |
|
|
Back-UPS CS Back-UPS CS
Click on the arrow to view more products
 |
 |
| ~ 5:01 (Hours : Minutes) |
~ 1:18 (Hours : Minutes) |
| Output |
| 980 Watts / 1500 VA |
280 Watts / 450 VA |
| 980 Watts / 1500 VA |
280 Watts / 450 VA |
| 230V |
| Configurable for 220 : 230 or 240 nominal output voltage |
-- |
| 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60
Hz nominal |
| up to 5 : 1 |
| Sine wave |
Stepped approximation to a sinewave |
(8) IEC 320 C13
(2) IEC Jumpers |
(4) IEC 320 C13
(2) IEC Jumpers |
| Input |
| 230V |
| 50/60 Hz +/- 3 Hz (auto sensing) |
| IEC-320 C14 |
| 160 - 286V |
| 151 - 302V |
|
Batteries & Runtime
|
| Maintenance-free sealed Lead-Acid battery with
suspended electrolyte : leakproof |
| 3 hour(s) |
5 hour(s) |
| RBC7 |
RBC18 |
| 1 |
|
Communications & Management
|
| DB-9 RS-232,SmartSlot,USB |
DB-9 RS-232 |
| 1 |
-- |
| LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : and Overload Indicators |
LED status display with On Line : On Battery : Replace
Battery and Overload indicators |
| Alarm when on battery : distinctive low battery alarm :
configurable delays |
Alarm when on battery : distinctive low battery alarm :
overload continuous tone alarm |
| Optional |
|
Surge Protection and Filtering
|
| 480 Joules |
320 Joules |
| Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.7% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
| -- |
RJ-11 2-Way Modem/Fax/DSL splitter with protection (four
wire dual lines),RJ45 10/100 Base-T Ethernet protection |
|
Physical
|
| 216.00 mm |
44.00 mm |
| 170.00 mm |
432.00 mm |
| 439.00 mm |
383.00 mm |
| 24.09 KG |
10.18 KG |
| 27.00 KG |
11.73 KG |
| 370.00 mm |
164.00 mm |
| 330.00 mm |
476.00 mm |
| 590.00 mm |
589.00 mm |
| Black |
Grey |
| 24.00 |
| -- |
1U |
|
Environmental
|
| 0 - 40 °C |
| 0 - 95% |
| 0-3000 meters |
| -15 - 45 °C |
| 0 - 95% |
| 0-15000 meters |
| 45.00 dBA |
38.00 dBA |
| 135.00 BTU/hr |
38.00 BTU/h |
|
Conformance
|
| C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
C-tick,CE,GOST,VDE |
| 2 years repair or replace |
| 2,3,11 |
|
|
|