| Output |
| 800 Watts / 1000 VA |
1425 Watts / 1500 VA |
| 800 Watts / 1000 VA |
1425 Watts / 1500 VA |
| 230V |
230V |
| Configurable for 220 : 230 or 240 nominal output voltage |
Configurable for 220 : 230 or 240 nominal output voltage |
| Less than 5% at full loadload |
Less than 5% at full load |
| 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
| up to 5 : 1 |
up to 5 : 1 |
| Sine wave |
Sine wave |
(8) IEC 320 C13
(2) IEC Jumpers |
(9) IEC 320 C13
(2) IEC Jumpers |
| |
95% |
| |
Internal Bypass (Automatic and Manual) |
| Input |
| 230V |
230V |
| 50/60 Hz +/- 5 Hz (auto sensing) |
50/60 Hz +/- 5 Hz (auto sensing) |
| IEC-320 C14 |
IEC-320 C14 |
| 1.83 meters |
|
| 160 - 285V |
160 - 285V |
| 151 - 302V |
151 - 302V |
| Batteries & Runtime |
| Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof |
VRLA |
| 3 hour(s) |
3 hour(s) |
| RBC7 |
RBC43 |
| 1 |
1 |
| |
1 |
| Communications and Management |
| DB-9 RS-232,SmartSlot,USB |
DB-9 RS-232,RJ-45 10/100 Base-T,USB |
| 1 |
|
| LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : and Overload Indicators |
LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : Overload and Bypass Indicators |
| Alarm when on battery : distinctive low battery alarm :
configurable delays |
Alarm when on battery : distinctive low battery alarm :
configurable delays |
| Optional |
Optional |
| |
AP9619 |
| Surge Protection and Filtering |
| 320 Joules |
490 Joules |
| Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
| Physical |
| 216.00 mm |
86.00 mm |
| 170.00 mm |
432.00 mm |
| 439.00 mm |
678.00 mm |
| 27.27 KG |
46.82 KG |
| 29.55 KG |
56.82 KG |
| 387.00 mm |
250.00 mm |
| 320.00 mm |
596.00 mm |
| 591.00 mm |
980.00 mm |
| Black |
Black |
| 24 |
8 |
| |
2U |
| Environmental |
| 0 - 40 °C |
0 - 40 °C |
| 0 - 95% |
0 - 95% |
| 0-3000 meters |
0-3000 meters |
| -15 - 45 °C |
-20 - 45 °C |
| 0 - 95% |
0 - 95% |
| 0-15000 meters |
0-9000 meters |
| 42 dBA |
55 dBA |
| 120 BTU/hr |
300.00 BTU/hr |
| Conformance |
| C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
C-tick,CE,EN 50091-2,EN 55022 Class A,EN 61000-3-2,GOST |
| 2 years repair or replace |
2 years repair or replace |
| |
|
| 2,3,11 |
2,3,11,12 |
Smart-UPS XL
Click on the arrows to view more products  
 |
 |
 |
| Output |
| 1980 Watts / 2200 VA |
1980 Watts / 2200 VA |
2700 Watts / 3000 VA |
| 1980 Watts / 2200 VA |
1980 Watts / 2200 VA |
2700 Watts / 3000 VA |
| 230V |
230V |
230V |
| Configurable for 220 : 230 or 240 nominal output voltage |
Configurable for 220 : 230 or 240 nominal output voltage |
Configurable for 220 : 230 or 240 nominal output voltage |
| 95% |
96% |
95% |
| Less than 5% at full load |
Less than 5% at full load |
Less than 5% at full load |
| 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60
Hz nominal |
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60
Hz nominal |
| up to 5 : 1 |
up to 5 : 1 |
up to 5 : 1 |
| Sine wave |
Sine wave |
Sine wave |
(8) IEC 320 C13
(1) IEC 320 C19
(2) IEC Jumpers |
(8) IEC 320 C13
(1) IEC 320 C19
(2) IEC Jumpers |
(8) IEC 320 C13
(1) IEC 320 C19
(2) IEC Jumpers |
| Input |
| 230V |
230V |
230V |
| 50/60 Hz +/- 5 Hz (auto sensing) |
50/60 Hz +/- 3 Hz (auto sensing) |
50/60 Hz +/- 5 Hz (auto sensing) |
IEC-320 C20
Schuko CEE 7 / EU1-16P
British BS1363A |
IEC-320 C20 Schuko CEE 7 / EU1-16P
British BS1363A |
IEC-320 C20
Schuko CEE 7 / EU1-16P
British BS1363A |
| 160 - 286V |
160 - 286V |
160 - 286V |
| 151 - 302V |
151 - 302V |
151 - 302V |
| |
1.83 meters |
|
| |
2-4 ms |
|
| Batteries & Runtime |
| Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof |
Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof |
Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof |
| 3 hour(s) |
3 hour(s) |
3 hour(s) |
| RBC55 |
APCRBC105 |
RBC55 |
| 1 |
1 |
1 |
| Communications and Management |
| DB-9 RS-232,SmartSlot,USB |
DB-9 RS-232,SmartSlot,USB |
DB-9 RS-232,SmartSlot |
| 1 |
1 |
1 |
| LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : and Overload Indicators |
LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : Overload and Bypass Indicators |
LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : and Overload Indicators |
| Alarm when on battery : distinctive low battery alarm :
configurable delays |
Alarm when on battery : distinctive low battery alarm :
configurable delays |
Alarm when on battery : distinctive low battery alarm :
configurable delays |
| Optional |
Optional |
Optional |
| Surge Protection and Filtering |
| 480 Joules |
480 Joules |
480 Joules |
| Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
| -- |
-- |
-- |
| Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
| Physical |
| 444.00 mm |
133.00 mm |
444.00 mm |
| 221.00 mm |
483 mm |
221.00 mm |
| 495.00 mm |
660 mm |
495.00 mm |
| 5U |
3U |
5U |
| 55.0 KG |
60.0 KG |
55.0 KG |
| 80.0 KG |
70.0 KG |
83.00 KG |
| 530.00 mm |
270.00 mm |
520.00 mm |
| 600.00 mm |
600.00 mm |
600.00 mm |
| 780.00 mm |
980.00 mm |
775.00 mm |
| Black |
Black |
Black |
| 3 |
8 |
3 |
| Environmental |
| 0 - 40 °C |
0 - 40 °C |
0 - 40 °C |
| 0 - 95% |
0 - 95% |
0 - 95% |
| 0-3000 meters |
0-3000 meters |
0-3000 meters |
| -15 - 45 °C |
-15 - 45 °C |
-15 - 45 °C |
| 0 - 95% |
0 - 95% |
0 - 95% |
| 0-15000 meters |
0-15000 meters |
0-15000 meters |
| 53 dBA |
53 dBA |
53 dBA |
| 305 BTU/hr |
375 BTU/hr |
305 BTU/hr |
| Conformance |
| C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
| 2 years repair or replace |
2 years repair or replace,optional on-site warranties
available,optional extended warranties available |
2 years repair or replace,optional on-site warranties
available,optional extended warranties available |
| 2,3 |
2,3 |
2,3 |
Smart-UPS XL Smart-UPS XL
Click on the arrow to view more products 
 |
 |
 |
| Output |
| 2850 Watts / 3000 VA |
2700 Watts / 3000 VA |
4000 Watts / 5000 VA |
| 2850 Watts / 3000 VA |
2700 Watts / 3000 VA |
4000 Watts / 5000 VA |
| 230V |
230V |
230V |
| Configurable for 220 : 230 or 240 nominal output voltage |
Configurable for 220 : 230 or 240 nominal output voltage |
Configurable for 220 : 230 or 240 nominal output voltage |
| 95% |
94% |
96% |
| Less than 5% at full loadload |
Less than 5% at full load |
Less than 5% at full load |
| 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
47 - 53 Hz for 50 Hz nominal |
| up to 5 : 1 |
up to 5 : 1 |
3 : 1 |
| Sine wave |
Sine wave |
Sine wave |
(7.0) IEC 320 C13
(1.0) IEC 320 C19
(2.0) IEC Jumpers |
(8.0) IEC 320 C13
(1.0) IEC 320 C19
(2.0) IEC Jumpers |
(8) IEC 320 C13
(2) IEC 320 C19
(4) IEC Jumpers |
| Internal Bypass (Automatic and Manual) |
-- |
-- |
| Input |
| 230V |
230V |
230V |
| 50/60 Hz +/- 5 Hz (auto sensing) |
50/60 Hz +/- 3 Hz (auto sensing) |
50/60 Hz +/- 3 Hz (auto sensing) |
| IEC-320 C20 |
IEC-320 C20 Schuko CEE 7 / EU1-16P
British BS1363A |
Hard Wire 3-wire |
| 160 - 285V |
160 - 286V |
160 - 286V |
| 151 - 302V |
151 - 302V |
151 - 302V |
| -- |
1.83 meters |
-- |
| -- |
220,240 |
-- |
| -- |
2-4 ms |
-- |
| Batteries & Runtime |
| VRLA |
Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof |
VRLA |
| 1 |
-- |
-- |
| 3 hour(s) |
3 hour(s) |
3 hour(s) |
| RBC43 |
APCRBC105 |
RBC55 |
| 1 |
1 |
2 |
| Communications and Management |
| DB-9 RS-232,RJ-45 10/100 Base-T,USB |
DB-9 RS-232,SmartSlot |
DB-9 RS-232,SmartSlot |
| AP9619 |
-- |
AP9630 |
| LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : Overload and Bypass Indicators |
LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : Overload and Bypass Indicators |
LED status display with load and battery bar-graphs and On
Line : On Battery : Replace Battery : and Overload Indicators |
| Alarm when on battery : distinctive low battery alarm :
configurable delays |
Alarm when on battery : distinctive low battery alarm :
configurable delays |
Alarm when on battery : distinctive low battery alarm :
configurable delays |
| Optional |
Optional |
-- |
| -- |
1 |
-- |
| Surge Protection and Filtering |
| 490 Joules |
480 Joules |
480 Joules |
| Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
Full time multi-pole noise filtering : 0.3% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
| -- |
-- |
-- |
| Physical |
| 86.00 mm |
133.00 mm |
222.00 mm |
| 432.00 mm |
483 mm |
483.00 mm |
| 678.00 mm |
660 mm |
660.00 mm |
| 2U |
3U |
5U |
| 46.82 KG |
62.73 KG |
97.73 KG |
| 56.82 KG |
74.00 KG |
106.82 KG |
| 250.00 mm |
290.00 mm |
635.00 mm |
| 596.00 mm |
600.00 mm |
610.00 mm |
| 980.00 mm |
990.00 mm |
762.00 mm |
| Black |
Black |
Black |
| 8 |
8 |
3 |
| Environmental |
| 0 - 40 °C |
0 - 40 °C |
0 - 40 °C |
| 0 - 95% |
0 - 95% |
0 - 95% |
| 0-3000 meters |
0-3000 meters |
0-3000 meters |
| -20 - 45 °C |
-15 - 45 °C |
-15 - 45 °C |
| 0 - 95% |
0 - 95% |
0 - 95% |
| 0-9000 meters |
0-15000 meters |
0-15000 meters |
| 55 dBA |
53 dBA |
53 dBA |
| 300 BTU/hr |
375 BTU/hr |
430 BTU/hr |
| Conformance |
| C-tick,CE,EN 50091-2,EN 55022 Class A,EN 61000-3-2,GOST |
C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE |
C-tick,CE,EN 50091-1,EN 50091-2,GOST,GS Mark,VDE |
| 2 years repair or replace |
2 years repair or replace,optional on-site warranties available,optional extended warranties available |
2 years repair or replace |
| 2,3,11,12 |
2,3,11 |
2,3,11 |
|